Quick Details

  • Condition: New
  • Type: Air-Cooled
  • Place of Origin: Shanghai, China (Mainland)
  • Brand Name: HAYE
  • Model Number: HYS-110AS
  • Cooling Capability(kw): 38.7kW
  • Voltage: 380V
  • Dimension(L*W*H): 2345mm 1500mm 2300mm
  • Weight: 1585kg
  • Certification: CE
  • After-sales Service Provided: Engineers available to service machinery overseas
  • Compressor: screw compressor
  • Cooling capacity: 114kW

Packaging & Delivery

Packaging Details To be packed in plywood pullet and plastic film or to be packaged with plywood box.
Delivery Time 20 days after receipt the 30% advance

   Air cooled screw water chiller

 

1.The main International advanced semi-closed screw compressor in which electric motor and compressor are organically integrated to ensure no leakage of the shaft sealing. Trouble-free operation over 100000hours.

 

2.Control programs for start and stoppage are applied to double or multiple compressors so as to balance the load and extend the service life of each component.

 

3.Several refrigeration circuits are provided for double or more compressors. When one circuit needs maintenance, other circuits can work properly as alternative circuits.

 

4. The compressor is started with unloading and decompression to avoid the impact to the power grid.

 

5.The vortex and propeller of the compressor is designed to ensure extremely low noise.

 

6. H/W structural design, favourable thermal radiation.

 

7.Heat exchanger has the national pressure vessel certificate.

 

8. 16 years experience

 

9. Accept orders for special requirements.

 

10. Use PLC microcomputer control from Germany Siemens LCD touch screen, both English and Chinese human-machine interface.

 

11. Fluoride-resistant high-performance motor from French.

 

 Accept orders for special requirements

 

1. R22 (1-2 compressors, 7°C)

Model[CHYS-**A(H)S3]160200240310360400480510550620
Cooling CapacitykW161198241311359396481509551621
×104 kcal/h13.91720.726.730.934.141.443.747.453.4
Heat CapacitykW178218265242395436529559606683
×104 kcal/h15.318.722.829.43437.545.548.152.158.8
30% Heat-recovery Capacity(kW)657896123142156192201221246
Total Refrigeration Input power(kW)54.562.88099.9115.1125.6160160.8184.5199.8
Total Heat Input power(kW)54.162.779.599.9114.6125.4159160.7184199.8
CompressorTypeTwin-screw semi-hermetic compressor advanced in the world
Quantityunit1111222222
Refrigeration Input powerkW47.758.271.191.1105.9116.4142.2149.3162.2182.2
Heat Input powerkW47587191105116141149162182
Energy Adjustment Step for Per Module25(start-up)-50-75-100%
RefrigerantSpecies——R22
Control——Thermal expansion valve External Balanced
FansQuantityunit4446888101012
Motor powerkW1.11.41.461.471.11.41.461.471.471.47
Air Side Heat ExchangerTypeCopper and aluminumfoil finned
Water Side Heat ExchangerTypeDry shell and tube high efficiency evaporator
Water Pipe ConnectionmmDN65DN80DN80DN150
Water flowm3/h283441536268838794106
Water Pressure DropkPa48525555444448485255
Safe Protection DeviceHigh&Low pressure protection, anti-freezing and anti-heating protection, safety valve, overload protection, incomplete phase protection, opposite phase protection, lacking voltage and over voltage protection, water flow protection, etc
DimensionsLongmm2050241028503550445548155695595063957095
Widemm2100210021002100210021002100210021002100
Highmm2253225322532253229322932293229322932293
Noise Valuedb(A)71717171757676777777
Total Weightkg1900209026603160399041805320525058206320
Running Weightkg2000224028103310421544055545547560456545
 1,The refrigeration conditions for the above table: cold water inlet temperature is 12°C, the outlet temperature is 7°C , and the ambient temperature is 35°C
 2. Power standard: 3N-380V-50Hz; Allow voltage fluctuation ± 10%, allowing phase voltage difference ± 2%;
 3. Noise analysis from the host location for the front of 2m, 1.5m high office, before and after the four-point average of left and right;
Notes:Dimensions for reference only, actual size drawings shall prevail.

 

2. R22 (3-4 compressors, 7°C)

Model[CHYS-**A(H)S3]68075082093010301100117012401340141014801550
Cooling CapacitykW67975181993210331102117212421343141314831553
×10³ kcal/h584646704801888948100810681155121512751335
Heat CapacitykW747826901102511361213128913661477155416311708
×10³ kcal/h6437108198819771043110911751271133714031469
30% Heat-recovery Capacity(kW)258299704369409437465493532560588616
Total Refrigeration Input power(kW)214.2245.3901299.8330.9353.8376.7399.7430.8453.7476.7499.6
Total Heat Input power(kW)213.1243.8775299.7329.3352.8376.2399.6429.5452.7476.1499.5
CompressorTypeTwin-screw semi-hermetic compressor advanced in the world
Quantityunit333344445555
Refrigeration Input powerkW200.4221.8240.4273.3304.4324.4344.4364.4395.5415.5435.5455.5
Heat Input powerkW199220240273303323344364394414435455
Energy Adjustment Step for Per Module25(start up)-50-75-100%
RefrigerantSpecies——R22
Control——Thermal expansion valve External Balanced
FansQuantityunit121616181820222424262830
Motor powerkW1.41.471.471.471.471.471.471.471.471.471.471.47
Air Side Heat ExchangerTypeCopper and aluminumfoil finned
Water Side Heat ExchangerTypeDry shell and tube high efficiency evaporator
Water Pipe ConnectionmmDN150+DN80DN150 X 2DN150 x 2+DN80DN150 x 2+DN100DN150 x 2+DN80DN150 x 2+DN100
Water flowm3/h116129140160177189201213230242254266
Water Pressure DropkPa444448484444484844444848
Safe Protection DeviceHigh&Low pressure protection, anti-freezing and anti-heating protection, safety valve, overload protection, incomplete phase protection, opposite phase protection, lacking voltage and over voltage protection, water flow protection, etc
DimensionsLongmm8105926595051046451209012790134901419015640163401704017740
Widemm210021002100210021002100210021002100210021002100
Highmm229322932293229322932293229322932293229322932293
Noise Valuedb(A)777878787878787878787979
Total Weightkg74108090841094801114011640121401264014300148001530015800
Running Weightkg76358315863597051136511865123651286514525150251552516025
 1,The refrigeration conditions for the above table: cold water inlet temperature is 12°C, the outlet temperature is 7°C , and the ambient temperature is 35°C
 2. Power standard: 3N-380V-50Hz; Allow voltage fluctuation ± 10%, allowing phase voltage difference ± 2%;
 3. Noise analysis from the host location for the front of 2m, 1.5m high office, before and after the four-point average of left and right;
Notes:Dimensions for reference only, actual size drawings shall prevail

 

3. R407C (1-2 compressors)

Air Cooled Screw Cold Water Unit Specification Table
Model[CHYS-N**A(H)S3]160200240310360400480510550620
Cooling CapacitykW158194236304352388472489540609
×10³ kcal/h136167203262303334406429465523
Heating CapacitykW168207251322375414502529573644
×10³ kcal/h144178216277323356432455493554
30% Heat-recovery Capacity(kW)647895123143157190201218246
Total Refrigeration Input power(kW)54.967.281.1105.3123.3134.5162.3172.8186.5210.6
Total Heat Input power(kW)55.468.281.9107124136.4163.9175.5189214
CompressorTypeTwin-screw semi-hermetic compressor advanced in the world
Quantityunit1111222222
Refrigeration Input powerkW50.561.675.396.5112.1123.3150.6158.1171.8192.9
Heat Input powerkW51637675.396.5112.1152161174196
Energy Adjustment Step for Per Module25(start up)-50-75-100%
RefrigerantSpecies——R22
Control——Thermal expansion valve External Balanced
FansQuantityunit4446888101012
Motor powerkW1.11.41.461.471.11.41.461.471.471.47
Air Side Heat ExchangerTypeCopper and aluminumfoil finned
Water Side Heat ExchangerTypeDry shell and tube high efficiency evaporator
Water Pipe ConnectionmmDN80DN100DN150
Water flowm3/h273340526067818593104
Water Pressure DropkPa48525555444448485255
Safe Protection DeviceHigh&Low pressure protection, anti-freezing and anti-heating protection, safety valve, overload protection, incomplete phase protection, opposite phase protection, lacking voltage and over voltage protection, water flow protection, etc
DimensionsLongmm2050241028503550445548155695595063957095
Widemm2100210021002100210021002100210021002100
Highmm2253225322532253229322932293229322932293
Noise Valuedb(A)71717171757676777777
Total Weightkg1900209026603160399041805320525058206320
Running Weightkg2000224028103310421544055545547560456545
 1,The refrigeration conditions for the above table: cold water inlet temperature is 12°C, the outlet temperature is 7°C , and the ambient temperature is 35°C
 2. Power standard: 3N-380V-50Hz; Allow voltage fluctuation ± 10%, allowing phase voltage difference ± 2%;
 3. Noise analysis from the host location for the front of 2m, 1.5m high office, before and after the four-point average of left and right;
Notes:Dimensions for reference only, actual size drawings shall prevail.

 

 

 


 

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Manufacturer, Trading Company
Transaction Level:
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $30,000
Learn More